Fault info. Meaning of CNC Plate punching Machine (2)

Supertime Engineers Department

CJ100 CNC hydraulic punching machine is mainly used for power transmission tower, communication towers or steel structure processing connection board processing, and other machinery industry of plate material, punching and marking.

:511 travel is beyond the soft limit, please re modify the location data.
:512 travel is beyond the soft limit, please re modify the positioning data.
:514: modify the current value out of range, please modify the current value in the set range.
:515 modify the current value is invalid, please do not specify the modified current value in the next continuous trajectory control of the positioning data.
:516 continuous path control is not valid, please do not specify a fixed stroke in the next location data; in the speed control or speed / position control and continuous trajectory control operation, the fixed stroke can not be performed.
:518 out of range, please modify the operation mode.
:519 other interpolation axis is busy, please modify the control mode.
:520 units do not match, please modify the location data or parameters.
:521 interpolation command is not correct, please modify the control mode.
:522 location speed error, please modify the positioning speed.
:524 control method set up an error, please modify the control mode or parameters.
:525 auxiliary point setting error, please modify arc address.
:526 Error occurred at the end of X, modify the location address.
:527 the center setting error, please modify the arc.
:530 address is out of range, please modify the location address.
:532 synchronous start is not valid. Please modify the special starting data and location data.
:533 condition data error, please reset the special starting data.
:534 special starting command error, please reset the special starting data.
:536 ON code M signal is connected to start, please M code ON signal after disconnection and then start.
:537 READY PC off when starting, please turn on the READY PC signal after the start.
538 READY AD75 on the start, please check the READY AD75 signal is disconnected and then start.
:543 out of the starting sequence number range, please reset the positioning start signal, that is, to stop running, to re download the program.
:544 out of the radius, please modify the location data.

:900 is beyond the scope of the unit settings, please re set the parameters within the valid range.
:901. The number of pulses per turn error, please re set the parameters within the valid range.
:902 per transfer error, please re set the parameters within the valid range.
:903 unit rate setting error, please re set the parameters in the valid range.
:904 pulse output mode error, please re set the parameters in the valid range.
:905 rotation direction setting error, please re set the parameters in the valid range.
:910 exceeds the speed limit, please re set the parameters within the valid range.
:911 out of the acceleration time range, please re set the parameters within the valid range.
:912 out of the deceleration time range, please reset the parameters within the valid range.
:913 out of range, please reset the parameters within the valid range.
:921 exceeds the soft limit limit, please re set the parameters within the effective range.
:922 exceeds the soft limit, please re set the parameters within the valid range.
:923 soft limit select set error, please re set the parameters in the valid range.
:924 soft limit setting error, please re set the parameters in the valid range.
:925 torque is not correct, please re set the parameters in the effective range.
:926 command range setting error, please re set the parameters within the valid range.
:927 M code on timing error, please re set the parameters in the valid range.
:928 speed switch mode error, please re set the parameters in the valid range.
:929 interpolation speed specified error, please re set the parameters in the effective range.
:930 update request error, please re set the parameters within the valid range.
:931 manual pulse generator selection error, please re set the parameters in the valid range.

More info. Please contact with:
Jinan Supertime Technology Co., Ltd.
www.jntime.com

没有评论: