Instruction of control system operation
⑴
Button Control Station operation
Use the rotary switch of Electrical cabinet operation
panel to adjust the Machine.
⑵ Panel Operation Introduction
All the operation buttons installed on the Electric
cabinet panel except a Foot Switch and program initiator, program stop,
hand-operate punching and scram button.
Function Introduction
1.Electric Source Operation Introduction
⑴ Main power switch, After insert the key to unlock, rotate the handle to the ON position, Flip the switch on, vice to rotating the handle to OFF, namely cut general power. Note, must keep the handle and air switch with the consistent position when close the electric cabinet door. Otherwise it will not be able to close the door.
1.Electric Source Operation Introduction
⑴ Main power switch, After insert the key to unlock, rotate the handle to the ON position, Flip the switch on, vice to rotating the handle to OFF, namely cut general power. Note, must keep the handle and air switch with the consistent position when close the electric cabinet door. Otherwise it will not be able to close the door.
⑵ Power
source Close/Open key button is used for electric source of control
circuit.
2. indicator
light instruction
⑴ Power light, it indicates the power
circuit is live when the key power switch is on.
⑵ Oil pump motor light indicates the
pump is started.
⑶ fault indicating light shows that
faults occur on servo motor, positioning module and machine. Click the corresponding
fault position on the PC screen to know the details.
⑷ ready light, after ready light up
the automatic system could launch, the conditions below:
① main punching cylinder, press cylinder,
press cylinder back to the toplimit
② X,Y axes back to the reference
point
③ dies are ready
④ on fault indicator light
⑤ materials are on the clamp
⑥ automatic state
3. button function:
⑴ pump start/stop button controls
the motor of oil pump.
⑵ clamp on/off and pedal on/off, to
infeed and outfeed the material. Before launch the automatic process the clamp
must on and the position plate must reset.
⑶ emergency button, press the button
during emergency, this function could shut down the power source of servo motor
and oil pump. After removal of breakdown, release the button and start the oil
pump again, press the break reset for 2 sec. to plug in the servo motor.
⑷ adjust/automatic switch is used to
choose the adjust state and automatic state.
Only under the conditions blow can use these buttons below:
① X axis motor forward/back switch, switch
to forward X axis(clamp) moves forward, release the switch then X axis stops
moving, on the contrary it goes back.
② Y axis motor forward/back switch,
it moves like the X axis to control the movement of Y axis(infeed table).
③ emergency reset, this button can
release the alarm when emergency light on.
④ die selection, artificially choose
die, one die changes at a time.
⑤ punching, used for artificial
punching, after oil pump stopped press this button can release the oil
pressure.
These buttons below can be used only
under automatic state:
① machine start, after the machine
is ready(ready light up),press this button with the indicating light, machine
starts to process; when machine pauses the light flashes, press again to
proceed the processing; after the program is over or stopped the machine, light
off. Notice: before the automatic launch, please set the parameters correctly,
and then transfer the work file, confirm the steps of the program and then
press the launch button again.
② program
stop, during the automatic processing, press once to pause the processing, X,Y
axes stop immediately, but die changing and punching continue to its end; press
twice, program stops. In addition, press the button during the artificial
positioning will interrupt the axis positioning and back to reference point.
More info. , please contact: