Supertime Technical
Department
1. No strong electricity on servo drive?
Check circuit
Check power module
Check drive module
Check servo power
supply air switch
2. Cable and
motor don’t match?
Motor encoder
feedback cable and power cable don’t match
Check motor
connection
No connection CNC
equipment and axis control cable of servo drive
Check axis control
cable
3. Interference of axis control cable?
Shielded twisted
pair cable should be adopted
Axis control cable
shouldn’t be wrapped
Axis control cable
should be kept away from other power cable, and shouldn’t be arranged parallel.
4. Adjust servo drive?
Check gain
adjustment parameter of servo drive, adjust and correct carefully parameter.
5. Incorrect parameter of servo drive?
Check control mode
of servo drive
Check pulse mode
of servo drive
Check motor level
of servo drive
Check motor
encoder feedback number of servo drive
6. Servo motor error?
Check output end
Check circuit
Check drive module
7. Mechanical connection problem?
Check bearing
Check junction gap
of bearing
Check screw